Page 1 - XDimensus300
P. 1

C251-E035



 Specifications  XDimensus 300

 Model: XDimensus 300
 Rated Power  135 W
 X-Ray Generator  Max. Tube Voltage  225 kV
 Max. Tube Current  1000 µA
 X-Ray Detector  Flat panel detector
 X-Ray Detector Size  16 inch  Dimensional X-Ray CT System
 X-Ray Detector Shades of Gray  16 bit, 65536 shades of gray
 Max. Sample Size and Weight  ø300 mm × H 300 mm, 10 kg max.  XDimensus 300
 Max. CT Scan Region  ø300 mm × H 210 mm
 Probing Error  |PS| + PF = 5.0  m* 2
 Measurement Accuracy* 1
 Sphere Distance Error  ± (3.8 + L/50)  m
 SRD Axis* 3  730 mm
 CT Stage Max. Stroke
 CT-Z Axis  300 mm
 CT Data Acquisition Time  20 min to 60 min
 Max. CT Image Size  2048 × 2048
 High-Performance Computing System  Yes
 Shield Box Size and Mass  W 2,195 mm × D 1,561 mm × H 1,971 mm, approx. 4,000 kg
 Air Conditioning Unit Size and Mass  W 832 mm × D 961 mm × H 1,529 mm, approx. 200 kg
 Specialized Desk Size and Mass  W 1,200 mm × D 700 mm × H 1,270 mm, approx. 50 kg
 Main Unit  Single-phase, AC 200 V ± 10%, 50/60 Hz, 4 kVA
 Air Conditioning Unit  Three-phase, AC 200 V ± 10%, 50/60 Hz, 2.6 kVA
 Power Requirements
 Control Computer  Single-phase, AC 100 V ± 10%, 50/60 Hz, 1.5 kVA
 Ground  Type-D ground (100 ohm max. ground resistance)
 Air Source  0.6 MPa to 1 MPa, 60 SLPM min.
 External Leakage Dose  1  Sv/h max.
 *1  Measurement Accuracy  Conformity to the VDE/VDI 2630 Part 1.3 standard
 *2  Probing Error   SRD = 200 mm, in the center of the fluoroscopic image
 *3  SRD Axis   The source-to-rotation center distance (SRD) is the distance from the X-ray source to the
    rotation center of the sample.




 Layout and Dimensional Drawings  (Units: mm)
 Air conditioning unit
 (space required for the air inlet and outlet)
 High-voltage
  transformer  Cooling water unit
 (961)
 (930)  (530)
 X-ray control box  (832) (1000)
 (2195)  (1561)  (605)  (360) (1000)


 (1971)  (3500)
 (1270)  (1202)
 (700)

 (700)  (1200)  Rack  XDimensus 300
 main unit
 Operation desk
 (4000)
 Recommended Installation Area: W 4000 mm × D 3500 mm











 For Research Use Only. Not for use in diagnostic procedures.
 This publication may contain references to products that are not available in your country. Please contact us to check the availability of these
 products in your country.
 Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its
 subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.
 Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not
 they are used with trademark symbol “TM” or “®”.
 Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
 www.shimadzu.com/an/  The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu
 does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
 © Shimadzu Corporation, 2017
 First Edition: December 2017, Printed in Japan 3655-12712-30ANS
   1   2   3   4   5   6