Page 11 - Shimadzu CELL PICKER
P. 11

Speci cations  Installation examples
























 CELL PICKERʴAUTO CHANGER  CELL PICKER


 ™
 Recommended Microscope  Olympus CKX 53

 Number of Vessels that  Up to 8
 can be Registered for Picking  Note: The only supported multi-well plates are 6-well plates.




 Number of Vessels that  Up to 8
 can be Registered for Seeding  Note: Not dishes however.    None



 Automated Seeding    Yes  No
               Related Item
 Recommended Pipette Tip  Manufacturer: QSP (Thermo Fisher Scienti c)
 (for 200 µL)  Model: TW110-96RNS-Q
               Desktop Clean Bench dedicated for
                                                                            Speci cations
               CELL PICKER (PCV-801TP-S3)                                   Size:         Outside Diameter
 Picking mode: 5/10/15 µL  Special clean bench that can be loaded on a                    W740 mm × D650 mm × H890 mm
 Suction amount                                                                           Inside
 Removal mode: 5 µL  laboratory desk.                                                     W690 mm × D520 mm × H605 mm
                                                                            Air  ow system:   Vertical air  ow system
              ɾ Ideal size for CELL PICKER.
                                                                            Room cleanliness:   ISO Class 4
 Weight  15.5 kg (AUTO CHANGER: 7 kg)  8.5kg  ɾ Utilize CELL PICKER easily due to adoption of a slide   Elements of dust-collecting: Pre- lter + HEPA  lter
                                                                                              3
                table.                                                      Air  ow:      6.4 m  / min ± 20%
                                                                            Power Supply:   65 W
              ɾ Fun Filter Unit maintains cleanliness when opening          Weight:       Approximately 75 Kg
 Size   W 585 mm×D536 mm×H456 mm  W 448 mm×D536 mm×H456 mm  the front shutter.  Note:     Slide table, Internal plug × 4
 (not including microscope)  ʢW 385 mm×D355 mm×H372 mmʣ  ʢW 248 mm×D355 mm×H372 mmʣ



 100 to 240 V AC, Frequency: 50/60 Hz,
 Power Supply
 Power consumption: 75 VA



 Operating temperature: 10 to 35 °C
 Environment
 Operating humidity: 20 to 85 %RH


                                                                                                CELL PICKER
 10                                                                                       Automated Picking and Collecting of Cell Colonies  11
   6   7   8   9   10   11   12