Page 5 - Shimadzu AIMsight
P. 5

AIMsight         AIMsight

 Powerful support for   High-sensitivity measurement

 an efficient analysis workflow










 Load Sample          Perform Ultra Micro Analysis
                      - Best-in-Class S/N Ratio -
               Measure
 Pressing the [Eject Sample] button makes it easy to load and   Measures samples
 remove samples by automatically lowering the stage and switching   up to 40 mm thick  The AIMsight has been optimized to measure extremely small areas. The AIMsight achieves a 30,000:1 S/N ratio, the best in its
 the objectives to expand space. Furthermore, the lower Condenser   class. Consequently, it can quickly obtain excellent spectra from even extremely small objects.
 mirror can be removed to enable reflectance/ATR measurements of
 samples up to 40 mm thick.
               Transmission measurement                             S/N:
               of polystyrene beads                                  30,000:1  Display peak intensity
                                                                             after modifying to
 Look for the Item to be Measured  ×1  ×5  A ø10  m polystyrene bead was   20,000:1 Abs  appropriate scale
 10×13mm
 2.0×2.6mm  ×33  measured by the transmission
 0.3×0.4mm  ×330                                               Abs
 Observe  Digital zoom  method. Low noise and a
 30×40 m
 Wide-Field Camera and Microscope Camera  high-quality spectrum of a very   4000     3200      2400  2000
                                                                                                    cm -1
               small sample were obtained
 The wide-field camera and microscope camera help observe samples   Sample  : 10  m diameter polystyrene
 efficiently. In addition to observing a large area up to 10 × 13 mm, the   with only a small number of     bead on BaF2 window plate
 wide-field camera also supports variable digital zooming. Furthermore,   scans.  Measurement  : Aperture size 15 × 15  m
                                         Condition
 by sharing positional information with the microscope camera, it   Number of Scans  : 40 (about 20 seconds)
 achieves a digital zoom function capable of zooming to a magnification   4000  3200  2400  1800  1400  1000
 of about 330× for observing areas as small as 30 × 40  m. (The micro-
 scope camera supports variable digital zoom magnifications up to 10×.)  Golden object on  Transmission spectra of 10  m diameter polystyrene bead
 a metal plate
                                                                obtained by two infrared microscopes with different noise levels.
 Determine Where to Measure, and Measure Automatically
                      High-Sensitivity ATR Measurement
 Measure
 Automatic Contaminant Recognition System (refer to page 8)  Measure  - Samples with High Refractive Index -

               Due to a steep incident angle for the infrared light, the AIMsight is able to acquire excellent distortion-free ATR spectra even
 Identify the Cause  when measuring samples with a high refractive index, such as black rubber. In addition, the Ge prism (P/N 206-32600-41) has
               an anti-reflective coating that provides high sensitivity.
 Analyze
 Contaminant Analysis Program                                                      0.5
 The contaminant analysis program - the functionality for automatically qualifying objects - is included as a standard feature   ATR measurement of   Abs
 ™
 in LabSolutions  IR software. Measured spectra using AIMsolution can be loaded directly into LabSolutions IR and analyzed.   black rubber  0.6  S/N:
 The contaminant analysis program identifies measured objects with high precision using a spectral library for substances   30,000:1  0.4
 commonly detected as contaminants in combination with Shimadzu's proprietary identification algorithm (Patent: JP   An acrylonitrilebutadiene   20,000:1
 5205918). Even if objects are mixtures, the system searches for the primary and secondary components, and displays the   0.4  1000  800
 probability of the substances identified. It is not necessary to specify the number of components in the mixture, so analysis   rubber (NBR) with 50 wt%   cm -1
 is easy, even for people with little experience with infrared analysis.  carbon was measured with a   Abs
               Ge-ATR objective. A clear peak
 Original library of high hit ratios (optional)  of C=C-H out-of-plane bending   Sample  : NBR with 50 wt% carbon   0.2
                                                   content
                                    -1
 Contaminant Library for LabSolutions IR (P/N 206-33179-91)  mode was obtained at 970 cm ,   Measurement
 This unique library was created by Shimadzu especially for analyzing contaminants in tap water and food products. The   which was strained with a   Condition  : Aperture size 50 × 50  m  0.0
                                         Number of Scans
                                                 : 20 (about 10 seconds)
 library includes information about samples collected as contaminants and service parts commercially marketed for tap water   gradual incident angle.
 applications. It also includes a collection of X-ray fluorescence profiles (PDF files). Consequently, it can significantly improve   4000  3000  2000  1500  1000  cm -1
 the qualitative accuracy of the objects. Unlike previous libraries, this is a mixture library that covers the extensive knowl-  ATR spectra of NBR with 50 wt% carbon obtained by two
 edge and experience necessary for qualitative analysis.            infrared microscopes with different noise levels.
 Thermal-Damaged Plastics Library*    P/N 206-33039-91 / UV-Damaged Plastics Library*    P/N 206-31808-41
 2
 1
 These unique libraries include information about plastics that have degraded due to oxidation by heating or Ultraviolet
 rays. The libraries are especially useful for analyzing degraded objects, which are common.
 *1 Shimadzu created the library using spectra obtained by Hamamatsu Technical Support Center, Industrial Research Institute of Shizuoka Prefecture.
 *2 Plastics which were degraded for 10 years worth by using an Iwasaki Electric super accelerated weathering tester were measured and compiled as a library
 by Shimadzu Corporation.